| Sign In | Join Free | My futurenowinc.com | 
 | 
Brand Name : GFUVE
Model Number : TEST-901B
Certification : ISO9001, CE, KEMA
Place of Origin : BEIJING CHINA
MOQ : 1SET
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 200SETS
Delivery Time : 7DAYS
Packaging Details : STANDARD EXPORT WOODEN BOX
NAME : PRIMARY CURRENT INJECTION TESTER
FUNCTION : TEST SWITCH (HIGH VOLTAGE CIRCUIT BREAKER)
RANGE : 0-1100A
ACCURACY : 0.5%
WITH TIMES : 0-999.99
HEAVY CURRENT 1000A CABLE : 6M
WEIGHT : 25KG
AMMETER : 0-6A
LCD : 320*240
Protection : overload electronic protection & software protection
TEST-901 PORTABLE 1000A SMART PRIMARY CURRENT INJECTION TESTER WITH 5KVA CAPICITY
PORTABLE 1000A SMART PRIMARY CURRENT INJECTION TESTER WITH 5KVA CAPICITY
TEST-901 1000A PRIMARY CURRENT INJECTION TESTER of circuit breaker adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 primary current injection test system is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.
This powerful test system is designed for primary injection testing of protective relay equipment and circuit breakers. It is also used to test the turns ratio of current transformers and for other applications that require high variable currents.
Primary current injection testing system is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
Primary injection testing system is suitable for testing over-current trip relays attached to a circuit breaker. By injecting the current into the system we can measure if the breaker will trip or fail, and how long the current is live before the circuit is broken.
Circuit breakers can go long periods of time without activation, and failure at the moment of activation can cause catastrophic damage to the electrical system. Circuit breaker testing with primary current injection on a breaker that has not triggered in some time is the best way to recreate the real operating conditions of a current spike.

FEATURES
| Electrical parameters | |
|---|---|
| Accuracy | ±0.5% | 
| Power Supply(AC) | 220V±10%·25A, 50Hz/60Hz or 110V±10%·50A, 50Hz/60Hz | 
| Current Output (AC) | 1000A·5V or 500A·10V | 
| Capacity | 5KVA | 
| The current output waveform distortion | ≤5% | 
| Dual protection | overload electronic protection and software protection | 
| Primary current | |
| Range | 0-1100A | 
| Resolution | 0.1A | 
| Accuracy | <0.5% | 
| Secondary measurement | |
| Range | 0-6A | 
| Resolution | 0.001A | 
| Accuracy | <0.5% | 
| Current duration | |
| 1000A range | 1000A 2-3minutes 500A 3-6minutes | 
| 500A range | 500A 2-3minutes | 
| With timer | |
| Range | 0.0001~999.99S | 
| Resolution | 0.001S | 
| Accuracy | <0.5%±5 words | 
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | 430×260×260 | 
| Weight(kg) | 25 | 
| Environmental conditions | |
| Temperature | -10°C to 40°C | 
| Relative humidity | ≤80% | 
| Model | ACCU RACY | Primary current | AMMETER (0-6A) | TIMER | POWER | INJECTION CURRENT TIME | DIMENSION(W×D×H)(mm) | WEIGHT | REMARK | 
|---|---|---|---|---|---|---|---|---|---|
| TEST-901 | 0.5% | 0-1100A | YES | YES | 5KVA | 1000A: 2-3min; 500A:3-6min | 430×260×260 | 25KG | Integrated structure | 
| TEST-902 | 0.5% | 0-2200A | YES | OPTIONAL | 12KVA | 2000A:2-3min; 1000A:3-6min | 360×300×295 and 320×300×300 | 35KG+15KG | Fission structure | 
| TEST-903 | 0.5% | 0-3300A | YES | OPTIONAL | 15KVA | 3000A:2-3min; 1500A:3-6min | 380×350×360 and 340×290×420 | 48KG+42KG | Fission structure | 
| TEST-905 | 0.5% | 0-5500A | YES | OPTIONAL | 25KVA | 5000A:2-3min; 2500A:3-6min | 430×430×445 and 550×450×600 | 68KG+55KG | Fission structure | 
|   | 
| Portable 1000a Smart Primary Injection Test Kit With 5kva Capicity Images | 
 5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing
                                                                                    
                        
                        
                        
                                                            5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing
                                                    
                        
                     Circuit Breaker 0.1A 5KVA Primary Injection Test Equipment
                                                                                        
                                                        
                        
                        
                        
                                                            Circuit Breaker 0.1A 5KVA Primary Injection Test Equipment
                                                    
                        
                     Large Current 1000a Primary Injection Test Equipment With Pc Panel 0.5% Accuracy
                                                                                        
                                                        
                        
                        
                        
                                                            Large Current 1000a Primary Injection Test Equipment With Pc Panel 0.5% Accuracy
                                                    
                        
                     Portable 1000a Primary Injection Test Equipment Circuit Breaker Tester
                                                                                        
                                                        
                        
                        
                        
                                                            Portable 1000a Primary Injection Test Equipment Circuit Breaker Tester
                                                    
                        
                     High Precision Primary Injection Test Equipment With 1000a Current Source
                                                                                        
                                                        
                        
                        
                        
                                                            High Precision Primary Injection Test Equipment With 1000a Current Source
                                                    
                        
                     GFUVE TEST-901 1000a Heavy Current Primary Injection Test Set For Ct Ratio Test
                                                                                        
                                                        
                        
                        
                        
                                                            GFUVE TEST-901 1000a Heavy Current Primary Injection Test Set For Ct Ratio Test
                                                    
                        
                     5000a 25kva Capicity Primary Current Injection Test Set For Power Transformer
                                                                                    
                        
                        
                        
                                                            5000a 25kva Capicity Primary Current Injection Test Set For Power Transformer
                                                    
                        
                     2000A Small Cart Primary Injection Test Equipment For Circuit Breakers
                                                                                    
                        
                        
                        
                                                            2000A Small Cart Primary Injection Test Equipment For Circuit Breakers
                                                    
                        
                     6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy
                                                                                    
                        
                        
                        
                                                            6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy
                                                    
                        
                     5000A 25KVA Primary Injection Test Equipment Primary Current Injection Test Kit
                                                                                    
                        
                        
                        
                                                            5000A 25KVA Primary Injection Test Equipment Primary Current Injection Test Kit